:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 869
:SBUS<n>:A429:SPEed
(see page 1610)
Command Syntax
:SBUS<n>:A429:SPEed <speed>
<speed> ::= {LOW | HIGH | USER}
The :SBUS<n>:A429:SPEed command specifies the signal speed:
• LOW — 12.5 kb/s.
• HIGH — 100 kb/s.
• USER — lets you specify a user-defined baud rate using the
:SBUS<n>:A429:BAUDrate command.
Query Syntax
:SBUS<n>:A429:SPEed?
The :SBUS<n>:A429:SPEed? query returns the current ARINC 429 signal speed
setting.
Return Format
<speed><NL>
<speed> ::= {LOW | HIGH | USER}
Errors • "-241, Hardware missing" on page 1551
See Also • ":SBUS<n>:A429:BAUDrate" on page 862
• "Introduction to :SBUS<n> Commands" on page 853
• ":SBUS<n>:MODE" on page 857
• ":SBUS<n>:A429:SIGNal" on page 867
• ":SBUS<n>:A429:FORMat" on page 866
• ":SBUS<n>:A429:SOURce" on page 868