1040 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:SENT:CLOCk
(see page 1610)
Command Syntax
:SBUS<n>:SENT:CLOCk <period>
<period> ::= the nominal clock period (tick), from 500 ns to 300 us,
in NR3 format.
The :SBUS<n>:SENT:CLOCk command specifies the nominal clock period (tick),
from 500 ns to 300 μs.
Query Syntax
:SBUS<n>:SENT:CLOCk?
The :SBUS<n>:SENT:CLOCk? query returns the clock period setting.
Return Format
<period><NL>
<period> ::= the nominal clock period (tick), from 500 ns to 300 us,
in NR3 format.
See Also ":SBUS<n>:SENT:CRC" on page 1041
":SBUS<n>:SENT:DISPlay" on page 1042
":SBUS<n>:SENT:FORMat" on page 1044
":SBUS<n>:SENT:IDLE" on page 1046
":SBUS<n>:SENT:LENGth" on page 1047
":SBUS<n>:SENT:PPULse" on page 1048
":SBUS<n>:SENT:SIGNal<s>:DISPlay" on page 1050
":SBUS<n>:SENT:SIGNal<s>:LENGth" on page 1051
":SBUS<n>:SENT:SIGNal<s>:MULTiplier" on page 1053
":SBUS<n>:SENT:SIGNal<s>:OFFSet" on page 1055
":SBUS<n>:SENT:SIGNal<s>:ORDer" on page 1057
":SBUS<n>:SENT:SIGNal<s>:STARt" on page 1059
":SBUS<n>:SENT:SOURce" on page 1061
":SBUS<n>:SENT:TOLerance" on page 1063
":SBUS<n>:SENT:TRIGger" on page 1064
":SBUS<n>:SENT:TRIGger:FAST:DATA" on page 1066
":SBUS<n>:SENT:TRIGger:SLOW:DATA" on page 1067
":SBUS<n>:SENT:TRIGger:SLOW:ID" on page 1069
":SBUS<n>:SENT:TRIGger:SLOW:ILENgth" on page 1071
":SBUS<n>:SENT:TRIGger:TOLerance" on page 1072