764 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
28 :POWer Commands
:POWer:PSRR:FREQuency:MINimum
(see page 1610)
Command Syntax
:POWer:PSRR:FREQuency:MINimum <value>[suffix]
<value> ::= {1 | 10 | 100 | 1000 | 10000 | 100000 | 1000000 | 10000000}
[suffix] ::= {Hz | kHz| MHz}
The :POWer:PSRR:FREQuency:MINimum command sets the start sweep
frequency value. The measurement is displayed on a log scale, so you can select
from decade values.
Query Syntax
:POWer:PSRR:FREQuency:MINimum?
The :POWer:PSRR:FREQuency:MINimum query returns the minimum sweep
frequency setting.
Return Format
<value><NL>
<value> ::= {1 | 10 | 100 | 1000 | 10000 | 100000 | 1000000 | 10000000}
See Also ":POWer:PSRR" on page 760
":POWer:PSRR:APPLy" on page 761
":POWer:PSRR:DATA" on page 762
":POWer:PSRR:FREQuency:MAXimum" on page 763
":POWer:PSRR:FREQuency:MODE" on page 765
":POWer:PSRR:PPDecade" on page 767
":POWer:PSRR:SOURce:INPut" on page 768
":POWer:PSRR:SOURce:OUTPut" on page 769
":POWer:PSRR:WGEN:LOAD" on page 771
":POWer:PSRR:WGEN:VOLTage" on page 772
":POWer:PSRR:WGEN:VOLTage:PROFile" on page 773

Table of Contents