:POWer Commands 28
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 801
:POWer:SWITch:VCE
(see page 1610)
Command Syntax
:POWer:SWITch:VCE <value>[suffix]
<value> ::= Vce(sat) value in NR3 format
[suffix] ::= {V | mV}
The :POWer:SWITch:VCE command specifies the Vce(sat) value when the VCE
conduction calculation method is chosen (by :POWer:SWITch:CONDuction).
Query Syntax
:POWer:SWITch:VCE?
The :POWer:SWITch:VCE query returns the Vce(sat) value.
Return Format
<value><NL>
<value> ::= Vce(sat) value in NR3 format
See Also • ":POWer:SWITch:APPLy" on page 797
• ":POWer:SWITch:CONDuction" on page 798
• ":POWer:SWITch:IREFerence" on page 799
• ":POWer:SWITch:RDS" on page 800
• ":POWer:SWITch:VREFerence" on page 802