1510 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
39 Obsolete and Discontinued Commands
:FUNCtion:GOFT:SOURce2
(see page 1610)
Command Syntax
:FUNCtion:GOFT:SOURce2 <value>
<value> ::= CHANnel<n>
<n>::={1|2|3|4}for4chmodels
<n> ::= {1 | 2} for 2ch models
The :FUNCtion:GOFT:SOURce2 command selects the second input channel for the
g(t) source that can be used as the input to transform or filter functions (if
available).
Query Syntax
:FUNCtion:GOFT:SOURce2?
The :FUNCtion:GOFT:SOURce2? query returns the current selection for the second
input channel for the g(t) source.
Return Format
<value><NL>
<value> ::= CHAN<n>
<n>::={1|2|3|4}for4chmodels
<n> ::= {1 | 2} for 2ch models
See Also • "Introduction to :FUNCtion<m> Commands" on page 460
• ":FUNCtion:GOFT:SOURce1" on page 1509
• ":FUNCtion:GOFT:OPERation" on page 1508