1206 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
32 :SEARch Commands
:SEARch:SERial:I2S:PATTern:FORMat
(see page 1610)
Command Syntax
:SEARch:SERial:I2S:PATTern:FORMat <base>
<base> ::= {BINary | HEX | DECimal}
The :SEARch:SERial:I2S:PATTern:FORMat command specifies the number base
used with the :SEARch:SERial:I2S:PATTern:DATA command.
Query Syntax
:SEARch:SERial:I2S:PATTern:FORMat?
The :SEARch:SERial:I2S:PATTern:FORMat? query returns the current number base
setting.
Return Format
<base><NL>
<base> ::= {BIN | HEX | DEC}
See Also Chapter 32, “:SEARch Commands,” starting on page 1149
":SEARch:SERial:I2S:PATTern:DATA" on page 1205