:ACQuire Commands 8
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 305
:ACQuire:DAALias
(see page 1610)
Command Syntax
:ACQuire:DAALias <mode>
<mode> ::= {DISable | AUTO}
The :ACQuire:DAALias command sets the disable anti-alias mode of the
oscilloscope.
When set to DISable, anti-alias is always disabled. This is good for cases where
dithered data is not desired.
When set to AUTO, the oscilloscope turns off anti-alias control as needed. Such
cases are when the FFT or differentiate math functions are silent. The :DIGitize
command always turns off the anti-alias control as well.
Query Syntax
:ACQuire:DAALias?
The :ACQuire:DAALias? query returns the oscilloscope's current disable anti-alias
mode setting.
Return Format
<mode><NL>
<mode> ::= {DIS | AUTO}
See Also • "Introduction to :ACQuire Commands" on page 300
• ":ACQuire:AALias" on page 302