920 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:CXPI:TRIGger:PATTern:ID
(see page 1610)
Command Syntax
:SBUS<n>:CXPI:TRIGger:PATTern:ID <string>
<string> ::= "nn...n" where n ::= {0 |1|X}
<string ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X}
For the trigger types that let you specify frame ID values in the trigger or allow
filtering by the frame ID, the :SBUS<n>:CXPI:TRIGger:PATTern:ID command lets
you specify the frame ID value.
Query Syntax
:SBUS<n>:CXPI:TRIGger:PATTern:ID?
The :SBUS<n>:CXPI:TRIGger:PATTern:ID? query returns the specified frame ID
value.
Returned frame ID values are always quoted binary format strings.
Return Format
<string><NL>
<string> ::= "nn...n" where n ::= {0 |1|X}
See Also • ":SBUS<n>:CXPI:TRIGger" on page 913
• ":SBUS<n>:CXPI:TRIGger:IDFilter" on page 915
• ":SBUS<n>:CXPI:TRIGger:PTYPe" on page 916
• ":SBUS<n>:CXPI:TRIGger:PATTern:DATA" on page 917
• ":SBUS<n>:CXPI:TRIGger:PATTern:DATA:LENGth" on page 918
• ":SBUS<n>:CXPI:TRIGger:PATTern:DATA:STARt" on page 919
• ":SBUS<n>:CXPI:TRIGger:PATTern:INFO:CT" on page 921
• ":SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC" on page 922
• ":SBUS<n>:CXPI:TRIGger:PATTern:INFO:NM" on page 923