912 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:CXPI:TOLerance
(see page 1610)
Command Syntax
:SBUS<n>:CXPI:TOLerance <percent>
<percent> ::= from 1-30, in NR1 format.
The :SBUS<n>:CXPI:TOLerance command specifies the tolerance as a percentage
of the Tbit width.
Query Syntax
:SBUS<n>:CXPI:TOLerance?
The :SBUS<n>:CXPI:TOLerance? query returns the tolerance setting.
Return Format
<percent><NL>
<percent> ::= from 1-30, in NR1 format.
See Also • ":SBUS<n>:CXPI:BAUDrate" on page 909
• ":SBUS<n>:CXPI:PARity" on page 910
• ":SBUS<n>:CXPI:SOURce" on page 911
• ":SBUS<n>:CXPI:TRIGger" on page 913