:DISPlay Commands 16
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 415
:DISPlay:GRATicule:INTensity
(see page 1610)
Command Syntax
:DISPlay:GRATicule:INTensity <value>
<value> ::= an integer from 0 to 100 in NR1 format.
The :DISPlay:GRATicule:INTensity command sets the graticule (grid) intensity.
Query Syntax
:DISPlay:GRATicule:INTensity?
The :DISPlay:GRATicule:INTensity? query returns the graticule (grid) intensity
setting.
Return Format
<value><NL>
See Also ":DISPlay:GRATicule:ALABels" on page 414
":DISPlay:GRATicule:TYPE" on page 416