120 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
5 Commands Quick Reference
:FUNCtion<m>:OPERatio
n <operation> (see
page 490)
:FUNCtion<m>:OPERatio
n? (see page 493)
<operation> ::= {ADD | SUBTract |
MULTiply | DIVide | INTegrate |
DIFF | FFT | FFTPhase | SQRT |
MAGNify | ABSolute | SQUare | LN
| LOG | EXP | TEN | LOWPass |
HIGHpass | AVERage | LINear |
MAXimum | MINimum | PEAK |
MAXHold | MINHold | TRENd |
BTIMing | BSTate}
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:RANGe
<range> (see page 494)
:FUNCtion<m>:RANGe?
(see page 494)
<range> ::= the full-scale
vertical axis value in NR3
format.
The range for ADD, SUBT, MULT is
8E-6 to 800E+3. The range for the
INTegrate function is 8E-9 to
400E+3.
The range for the DIFF function
is 80E-3 to 8.0E12 (depends on
current sweep speed).
The range for the FFT function is
8 to 800 dBV.
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:REFerenc
e <level> (see
page 495)
:FUNCtion<m>:REFerenc
e? (see page 495)
<level> ::= the value at center
screen in NR3 format.
The range of legal values is
+/-10 times the current
sensitivity of the selected
function.
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:SCALe
<scale
value>[<suffix>] (see
page 496)
:FUNCtion<m>:SCALe?
(see page 496)
<scale value> ::= integer in NR1
format
<suffix> ::= {V | dB}
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:SMOoth:P
OINts <points> (see
page 497)
:FUNCtion<m>:SMOoth:P
OINts? (see page 497)
<points> ::= odd integer in NR1
format
Table 16 :FUNCtion<m> Commands Summary (continued)
Command Query Options and Query Returns