:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 969
:SBUS<n>:IIC:TRIGger:PATTern:DATa2
(see page 1610)
Command Syntax
:SBUS<n>:IIC:TRIGger:PATTern:DATa2 <value>
<value> ::= integer or <string>
<string> ::= "0xnn" where n ::= {0,..,9 | A,..,F}
The :SBUS<n>:IIC:TRIGger:PATTern:DATa2 command sets IIC data 2. The data
value can range from 0x00 to 0x0FF (hexadecimal). Use the don't care data pattern
(-1 or 0xFFFFFFFF) to ignore the data value.
Query Syntax
:SBUS<n>:IIC:TRIGger:PATTern:DATa2?
The :SBUS<n>:IIC:TRIGger:PATTern:DATa2? query returns the current pattern for
IIC data 2.
Return Format
<value><NL>
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":SBUS<n>:IIC:TRIGger:PATTern:ADDRess" on page 967
• ":SBUS<n>:IIC:TRIGger:PATTern:DATA" on page 968
• ":SBUS<n>:IIC:TRIGger[:TYPE]" on page 971