982 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:LIN:TRIGger
(see page 1610)
Command Syntax
:SBUS<n>:LIN:TRIGger <condition>
<condition> ::= {SYNCbreak | ID | DATA | PARityerror | CSUMerror
| FRAMe | FSIGnal}
The :SBUS<n>:LIN:TRIGger command sets the LIN trigger condition to be:
•SYNCbreak — Sync Break.
•ID — Frame ID.
Use the :SBUS<n>:LIN:TRIGger:ID command to specify the frame ID.
• DATA — Frame ID and Data.
Use the :SBUS<n>:LIN:TRIGger:ID command to specify the frame ID.
Use the :SBUS<n>:LIN:TRIGger:PATTern:DATA:LENGth and
:SBUS<n>:LIN:TRIGger:PATTern:DATA commands to specify the data string
length and value.
• PARityerror — parity errors.
• CSUMerror — checksum errors.
• FRAMe — Triggers on a symbolic frame.
• FSIGnal — Triggers on a symbolic frame and a signal value.
Query Syntax
:SBUS<n>:LIN:TRIGger?
The :SBUS<n>:LIN:TRIGger? query returns the current LIN trigger value.
Return Format
<condition><NL>
<condition> ::= {SYNC | ID | DATA | PAR | CSUM | FRAM | FSIG}
Errors • "-241, Hardware missing" on page 1551
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":TRIGger:MODE" on page 1308
• ":SBUS<n>:LIN:TRIGger:ID" on page 984
• ":SBUS<n>:LIN:TRIGger:PATTern:DATA:LENGth" on page 987
• ":SBUS<n>:LIN:TRIGger:PATTern:DATA" on page 985
• ":SBUS<n>:LIN:SIGNal:DEFinition" on page 1543
• ":SBUS<n>:LIN:SOURce" on page 979
• ":RECall:LDF[:STARt]" on page 815
• ":SBUS<n>:LIN:TRIGger:SYMBolic:FRAMe" on page 989
• ":SBUS<n>:LIN:TRIGger:SYMBolic:SIGNal" on page 990