EasyManuals Logo

Keysight Technologies InfiniiVision 4000 X Series User Manual

Keysight Technologies InfiniiVision 4000 X Series
1762 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #582 background imageLoading...
Page #582 background image
582 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
24 :MEASure Commands
:MEASure:DELay:DEFine
(see page 1610)
Command Syntax
:MEASure:DELay:DEFine <source1_edge_slope>, <source1_edge_number>,
<source1_edge_threshold>, <source2_edge_slope>,
<source2_edge_number>, <source2_edge_threshold>
<source1_edge_slope>,
<source2_edge_slope> ::= {RISing | FALLing}
<source1_edge_number>,
<source2_edge_number> ::= 0 to 1000 in NR1 format
<source1_edge_threshold>,
<source2_edge_threshold> ::= MIDDle
The :MEASure:DELay:DEFine command defines slope directions and edge
numbers for the delay measurement started or returned by the :MEASure:DELay
command. The :MEASure:DELay:DEFine command also defines edge position
parameters, but currently, MIDDle is the only valid selection.
A <source1_edge_number> setting of zero (0) specifies that the edge closest to the
timebase reference point automatically be selected. In this case, the
<source2_edge_number> setting must also be zero (0), and the source2 edge
closest to the selected source1 edge is used.
When edge numbers greater than zero (0) are specified, edges are counted from
the left side of the display for both sources.
The selection of the source1 and source2 waveforms is made in the
:MEASure:DELay or :MEASure:SOURce commands.
Query Syntax
:MEASure:DELay:DEFine?
The :MEASure:DELay:DEFine? query returns the specified delay measurement
parameter definitions.
Return Format
<source1_edge_slope>, <source1_edge_number>,
<source1_edge_threshold>, <source2_edge_slope>,
<source2_edge_number>,<source2_edge_threshold><NL>
<source1_edge_slope>,
<source2_edge_slope> ::= {RIS | FALL}
<source1_edge_number>,
<source2_edge_number> ::= 0 to 1000 in NR1 format
<source1_edge_threshold>,
<source2_edge_threshold> ::= MIDD
See Also • ":MEASure:DELay" on page 580
• ":MEASure:SOURce" on page 615
• ":MEASure:DEFine" on page 577

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 4000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 4000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 4000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals