:SEARch Commands 32
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 1247
:SEARch:SERial:USB:DATA:LENGth
(see page 1610)
Command Syntax
:SEARch:SERial:USB:DATA:LENGth <length>
<length> ::= data length between 1-20
The :SEARch:SERial:USB:DATA:LENGth command specifies the data length in
bytes.
Query Syntax
:SEARch:SERial:USB:DATA:LENGth?
The :SEARch:SERial:USB:DATA:LENGth? query returns the specified data length.
Return Format
<length><NL>
<length> ::= data length between 1-20
See Also • ":SEARch:SERial:USB:DATA" on page 1246