:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 933
:SBUS<n>:FLEXray:SOURce
(see page 1610)
Command Syntax
:SBUS<n>:FLEXray:SOURce <source>
<source> ::= {CHANnel<n>}
<n>::={1|2|3|4}
The :SBUS<n>:FLEXray:SOURce command specifies the input source for the
FlexRay signal.
Query Syntax
:SBUS<n>:FLEXray:SOURce?
The :SBUS<n>:FLEXray:SOURce? query returns the current source for the FlexRay
signal.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 1295
":SBUS<n>:FLEXray:TRIGger" on page 934
":SBUS<n>:FLEXray:TRIGger:EVENt:TYPE" on page 938
":SBUS<n>:FLEXray:AUTosetup" on page 926