344 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
11 :CHANnel<n> Commands
:CHANnel<n>:PROBe
<attenuation> (see
page 354)
:CHANnel<n>:PROBe?
(see page 354)
<attenuation> ::= Probe
attenuation ratio in NR3 format
<n> ::= 1-2 or 1-4; in NR1 format
:CHANnel<n>:PROBe:HEA
D[:TYPE] <head_param>
(see page 355)
:CHANnel<n>:PROBe:HEA
D[:TYPE]? (see
page 355)
<head_param> ::= {SEND0 | SEND6 |
SEND12 | SEND20 | DIFF0 | DIFF6 |
DIFF12 | DIFF20 | DSMA | DSMA6 |
NONE}
<n> ::= 1 to (# analog channels)
in NR1 format
n/a :CHANnel<n>:PROBe:ID?
(see page 356)
<probe id> ::= unquoted ASCII
string up to 11 characters
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROBe:MMO
Del <value> (see
page 357)
:CHANnel<n>:PROBe:MMO
Del? (see page 357)
<value> ::= {P5205 | P5210 |
P6205 | P6241 | P6243 | P6245 |
P6246 | P6247 | P6248 | P6249 |
P6250 | P6251 | P670X | P671X |
TCP202}
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROBe:RSE
Nse <value> (see
page 358)
:CHANnel<n>:PROBe:RSE
Nse? (see page 358)
<value> ::= Ohms in NR3 format
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROBe:SKE
W <skew_value> (see
page 359)
:CHANnel<n>:PROBe:SKE
W? (see page 359)
<skew_value> ::= -100 ns to +100
ns in NR3 format
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROBe:STY
Pe <signal type> (see
page 360)
:CHANnel<n>:PROBe:STY
Pe? (see page 360)
<signal type> ::= {DIFFerential |
SINGle}
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROBe:ZOO
M {{0 | OFF} | {1 |
ON}} (see page 361)
:CHANnel<n>:PROBe:ZOO
M? (see page 361)
<setting> ::= {0 | 1}
<n> ::= 1 to (# analog channels)
in NR1 format
:CHANnel<n>:PROTectio
n (see page 362)
:CHANnel<n>:PROTectio
n? (see page 362)
{NORM | TRIP}
<n> ::= 1 to (# analog channels)
in NR1 format
Table 97 :CHANnel<n> Commands Summary (continued)
Command Query Options and Query Returns