1260 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
33 :SYSTem Commands
Introduction to
:SYSTem
Commands
SYSTem subsystem commands enable writing messages to the display, setting
and reading both the time and the date, querying for errors, and saving and
recalling setups.
:SYSTem:RLOGger
<setting>[,<file_name
>[,<write_mode>]]
(see page 1270)
n/a <setting> ::= {{0 | OFF} | {1 |
ON}}
<file_name> ::= quoted ASCII
string
<write_mode> ::= {CREate |
APPend}
:SYSTem:RLOGger:DESTi
nation <dest> (see
page 1271)
:SYSTem:RLOGger:DESTi
nation? (see
page 1271)
<dest> ::= {FILE | SCReen | BOTH}
:SYSTem:RLOGger:DISPl
ay {{0 | OFF} | {1 |
ON}} (see page 1272)
:SYSTem:RLOGger:DISPl
ay? (see page 1272)
<setting> ::= {0 | 1}
:SYSTem:RLOGger:FNAMe
<file_name> (see
page 1273)
:SYSTem:RLOGger:FNAMe
? (see page 1273)
<file_name> ::= quoted ASCII
string
:SYSTem:RLOGger:STATe
{{0 | OFF} | {1 |
ON}} (see page 1274)
:SYSTem:RLOGger:STATe
? (see page 1274)
<setting> ::= {0 | 1}
:SYSTem:RLOGger:TRANs
parent {{0 | OFF} |
{1 | ON}} (see
page 1275)
:SYSTem:RLOGger:TRANs
parent? (see
page 1275)
<setting> ::= {0 | 1}
:SYSTem:RLOGger:WMODe
<write_mode> (see
page 1276)
:SYSTem:RLOGger:WMODe
? (see page 1276)
<write_mode> ::= {CREate |
APPend}
:SYSTem:SETup
<setup_data> (see
page 1277)
:SYSTem:SETup? (see
page 1277)
<setup_data> ::= data in IEEE
488.2 # format.
:SYSTem:TIME <time>
(see page 1279)
:SYSTem:TIME? (see
page 1279)
<time> ::= hours,minutes,seconds
in NR1 format
:SYSTem:TOUCh {{1 |
ON} | {0 | OFF}} (see
page 1280)
:SYSTem:TOUCh? (see
page 1280)
{1 | 0}
Table 150 :SYSTem Commands Summary (continued)
Command Query Options and Query Returns

Table of Contents