Table 50 :SEARch:SERial:CAN Commands Summary
Command Query Options and Query Returns
:SEARch:SERial:CAN:MO
DE <value> (see
page 1187)
:SEARch:SERial:CAN:MO
DE? (see page 1187)
<value> ::= {IDEither | IDData |
DATA | IDRemote | ERRor |
ACKerror | FORMerror | STUFferror
| CRCerror | ALLerrors | OVERload
| MESSage | MSIGnal}
:SEARch:SERial:CAN:PA
TTern:DATA <string>
(see page 1189)
:SEARch:SERial:CAN:PA
TTern:DATA? (see
page 1189)
<string> ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X} for
hexadecimal
:SEARch:SERial:CAN:PA
TTern:DATA:LENGth
<length> (see
page 1190)
:SEARch:SERial:CAN:PA
TTern:DATA:LENGth?
(see page 1190)
<length> ::= integer from 1 to 8
in NR1 format
:SEARch:SERial:CAN:PA
TTern:ID <string>
(see page 1191)
:SEARch:SERial:CAN:PA
TTern:ID? (see
page 1191)
<string> ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X} for
hexadecimal
:SEARch:SERial:CAN:PA
TTern:ID:MODE <value>
(see page 1192)
:SEARch:SERial:CAN:PA
TTern:ID:MODE? (see
page 1192)
<value> ::= {STANdard | EXTended}
:SEARch:SERial:CAN:SY
MBolic:MESSage <name>
(see page 1193)
:SEARch:SERial:CAN:SY
MBolic:MESSage? (see
page 1193)
<name> ::= quoted ASCII string
:SEARch:SERial:CAN:SY
MBolic:SIGNal <name>
(see page 1194)
:SEARch:SERial:CAN:SY
MBolic:SIGNal? (see
page 1194)
<name> ::= quoted ASCII string
:SEARch:SERial:CAN:SY
MBolic:VALue <data>
(see page 1195)
:SEARch:SERial:CAN:SY
MBolic:VALue? (see
page 1195)
<data> ::= value in NR3 format
Table 51 :SEARch:SERial:FLEXray Commands Summary
Command Query Options and Query Returns
:SEARch:SERial:FLEXra
y:CYCLe <cycle> (see
page 1197)
:SEARch:SERial:FLEXra
y:CYCLe? (see
page 1197)
<cycle> ::= {ALL | <cycle #>}
<cycle #> ::= integer from 0-63
:SEARch:SERial:FLEXra
y:DATA <string> (see
page 1198)
:SEARch:SERial:FLEXra
y:DATA? (see
page 1198)
<string> ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X }
:SEARch:SERial:FLEXra
y:DATA:LENGth
<length> (see
page 1199)
:SEARch:SERial:FLEXra
y:DATA:LENGth? (see
page 1199)
<length> ::= integer from 1 to 12
in NR1 format

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 4000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 4000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 4000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals