Parameter
List of parameters
1-112
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: p0404
Note: ZM: Zero mark
This parameter is only used for diagnostics.
A value of zero is displayed if an encoder is not present.
Description: Sets the Sensor Module configuration.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
02 Multiturn encoder Yes No -
03 Track A/B sq-wave Yes No -
04 Track A/B sinus Yes No -
05 Track C/D Yes No -
06 Hall sensor Yes No -
08 EnDat encoder Yes No -
09 SSI encoder Yes No -
10 DRIVE-CLiQ encoder Yes No -
11 Digital encoder Yes No -
12 Equidistant zero mark Yes No -
13 Irregular zero mark Yes No -
14 Distance-coded zero mark Yes No -
15 Commutation with zero mark (not ASM) Yes No -
16 Acceleration Yes No -
17 Track A/B analog Yes No -
20 Voltage level 5 V Yes No -
21 Voltage level 24 V Yes No -
22 Remote sense (only SMC30) Yes No -
23 Resolver excit. Yes No -
r0458[0...2] Sensor Module properties / SM properties
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Encoder data available Yes No -
01 Motor data available Yes No -
02 Temperature sensor connection available Yes No -
03 Connection for PTC for motor with DRIVE-
CLiQ also available
Yes No -
04 Module temperature available Yes No -
05 Absolute encoder p0408/p0421, no power
of 2
Yes No -
06 Sensor Module permits parking/unparking Yes No -
07 Hall sensor can be combined with actual
value inversion
Yes No -
08 Evaluation through several temperature
channels possible
Yes No -
09 Encoder fault and its associated information
available
Yes No -
10 Speed diagnostics in the Sensor Module Yes No -
11 Configuring without park state possible Yes No -
12 Extended functions available Yes No -
13 Extended encoder fault handling Yes No -
14 Extended singleturn/multiturn information
available
Yes No -
15 Valuation figures available Yes No -
16 Pole position identification Yes No -
17 Burst oversampling Yes No -