Siemens SINAMICS S110 - p1525[0...n] CO: Torque limit lower;regenerative scaling; M_max low;gen scal; r1526 CO: Torque limit upper;motoring without offset; M_max up w;o offs; r1527 CO: Torque limit lower;regenerative without offset; M_max low w;o offs; p1528[0...n] CI: Torque limit upper;motoring scaling; M_max up;mot scal

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-254
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note: This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
Description: Sets the scaling for the lower torque limit or the torque limit when regenerating.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
Description: Displays the upper torque limit of all torque limits without offset.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Description: Displays the lower torque limit of all torque limits without offset.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Description: Sets the signal source for the scaling of the upper or motoring torque limit in p1522.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
p1525[0...n] CO: Torque limit lower/regenerative scaling / M_max low/gen scal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5620, 5630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
r1526 CO: Torque limit upper/motoring without offset / M_max up w/o offs
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 5620, 5630
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1527 CO: Torque limit lower/regenerative without offset / M_max low w/o offs
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 5620, 5630
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
p1528[0...n] CI: Torque limit upper/motoring scaling / M_max up/mot scal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 3617,
5620, 5630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1524[0]