Parameter
List of parameters
1-184
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Resets or downloads all parameters of the drive system.
Value: 0: Inactive
1: Start reset of all parameters to factory setting
2: Start dnload of param. saved in non-volatile mem w/ p0977=1
3: Start dnload of volatile parameters from RAM
10: Start dnload of param. saved in non-volatile mem w/ p0977=10
11: Start dnload of param. saved in non-volatile mem w/ p0977=11
12: Start dnload of param. saved in non-volatile mem w/ p0977=12
20: Start download Siemens internal setting 20
21: Start download Siemens internal setting 21
22: Start download Siemens internal setting 22
23: Start download Siemens internal setting 23
24: Start download Siemens internal setting 24
25: Start download Siemens internal setting 25
26: Start download Siemens internal setting 26
100: Start resetting of all BICO interconnections
1011: Start dnload of param. saved in volatile mem w/ p0977=1011
1012: Start dnload of param. saved in volatile mem w/ p0977=1012
1013: Start dnload of param. saved in volatile mem w/ p0977=1013
Notice: After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note: After all of the parameters have been reset to their factory setting, the system must be commissioned for the first
time again.
Resetting or loading is realized in the non-volatile memory.
Procedure:
1. Set p0009 = 30 (parameter reset).
2. Set p0976 to "required value". The system is rebooted.
p0976 is automatically set to 0 and p0009 is automatically set to 1 after this has been carried out.
Description: Saves all parameters of the drive system to the non-volatile memory.
Value: 0: Inactive
1: Save in non-volatile memory - downloaded at POWER ON
10: Save as opt. in non-vol. memory - downloaded w/ p0976=10
11: Save as opt. in non-vol. memory - downloaded w/ p0976=11
12: Save as opt. in non-vol. memory - downloaded w/ p0976=12
20: Save in non-volatile memory as setting 20 (reserved)
21: Save in non-volatile memory as setting 21 (reserved)
22: Save in non-volatile memory as setting 22 (reserved)
23: Save in non-volatile memory as setting 23 (reserved)
24: Save in non-volatile memory as setting 24 (reserved)
25: Save in non-volatile memory as setting 25 (reserved)
26: Save in non-volatile memory as setting 26 (reserved)
80: Save in non-volatile memory time-optimized (reserved)
p0976 Reset and load all parameters / Reset load all par
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1(30) Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Factory settings Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1013 0
p0977 Save all parameters / Save all par
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Factory settings Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1013 0