Parameter
List of parameters
1-92
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the motor stator resistance at an ambient temperature (p0625).
The value does not include the cable resistance.
Dependency: Refer to: p0625
Description: Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency: Refer to: p0627
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rotor/secondary section resistance of the motor for the ambient temperature p0625.
For separately-excited synchronous motors: Displays the damping resistance in the rotor direction (d-axis).
Dependency: Refer to: p0625
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rated (nominal) rotor/secondary section resistance of the motor at the rated temperature (total of
p0625 and p0628).
Dependency: Refer to: p0628
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
r0370[0...n] Motor stator resistance, cold / Mot R_stator cold
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0373[0...n] Motor rated stator resistance / Mot R_stator rated
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0374[0...n] Motor rotor resistance cold / damping resistance d axis / Mot R_r cold / RDd
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0376[0...n] Rated motor rotor resistance / Mot R_rotor rated
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]