EasyManuals Logo

Siemens SINAMICS S110 List Manual

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #830 background imageLoading...
Page #830 background image
Function diagrams
Brake control
2-830
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-70 2701 – Basic brake control (r0108.14 = 0)
- 2701 -
Function diagram
87654321
fp_2701_98_eng.vsd
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Braking control - Basic braking control (r0108.14 = 0)
n_stop n_thresh
0.0...210 000.0 [rpm]
p1226 (20.0)
r0060
n_set before filter
[5020.4]
Pulse enable HW
OFF 1 present
OFF 3 present
<3> If p1215 = 0, 2 -> t = 0 ms.
Background
Refer to [1020.7]
<1> Motor holding brake configuration (p1215)
0 = No motor holding brake being used.
1 = Motor holding brake acc. to sequence control.
2 = Motor holding brake always released.
3 = Motor holding brake like sequence control, connection via BICO.
<4> Only if Safety Integrated is active.
<5> For p1227 = 300 s, the monitoring function is deactivated.
Stop 2 enable internal missing
r0046.21 [2634.1]
<2> Priority assignment (high -> low): p1215, p0858, p0855, p0856, sequence control.
[2501.3]
p0855
1 = Unconditionally open the
holding brake
r0898.7
<6> If an external motor holding brake is used, p1215 should be set to 3 and r0899.12 should be interconnected as
control signal.
<3>
<8> The internal signal includes signals that lead to OFF1 or OFF3 (e. g. BICO or fault response).
<9> If the brake is permanently applied or released (p0855, p0858 or p1215), the drive does not wait while the brake is released or applied.
[2501.3]
p0856 1 = Enable speed controller
r0898.12
[2501.3]
p0852 1 = Operation enabled
r0898.3
<7> r0046.21 = 0, as long as r0046.0 = 1 (OFF1 enable missing or power-on inhibit).
r0046.21 = 1, if p0858 = 1 or p0856 = 0.
The signal generation is shown simplified.
[2501.3]
p0858 1 = Unconditionally close the holding brake
r0898.14
0...10 000 [ms]
p1217 (100)
1
T0
0.000...300.000 [s]
p1227 (4.000)
T0
p1215 = 2
1
0
1
0
T0
1
1
1
<4>
T0
0.000...10.000 [s]
p1228 (0.000)
[2814.2]
[2503.3]
[2503.3]
[2610.5]
[2610.8]
[5042.8]
[5730.4]
&
<5>
<1>
<2>
<2>
<6>
[2503.3]
<3>
<7>
<8>
[2503.7]
Q
Q
RESET
(Q=0)
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
RESET
(Q=0)
Q
Q
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
0...10 000 [ms]
p1216 (100)
<1>
p1215 = 0
&
&
&
1
&
1 = Command, close holding brake
r0899.13
Close "normal" brake
1 = Open the holding brake
1 = Open holding brake
r0899.12
Open brake
Close brake
r0063
n_act smooth
[4710.6]
1 = No coast down active
r0899.4
Pulse enable X21
[2503.7]
1 = Power-on inhibit active
r0899.6
Magnetizing completed
r0056.4
<9>
[2526.6]
Note: Braking signal diagnostic evaluation (p1278) only applies for SBC (Safe Brake Control) (controls the Safe Brake Relay).

Table of Contents

Other manuals for Siemens SINAMICS S110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S110 and is the answer not in the manual?

Siemens SINAMICS S110 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S110
CategoryMedia Converter
LanguageEnglish

Related product manuals