List of parameters
Parameter
1-95
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency: In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note: In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
Description: Displays the actual rotor/secondary section resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency: Refer to: p0354, p0620
Note: In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
Description: Selects the encoder from the list of encoder types supported.
Value: 0: No encoder
202: DRIVE-CLiQ encoder AS20, singleturn
204: DRIVE-CLiQ encoder AM20, multiturn 4096
242: DRIVE-CLiQ encoder AS24, singleturn
244: DRIVE-CLiQ encoder AM24, multiturn 4096
1001: Resolver 1 speed
1002: Resolver 2 speed
1003: Resolver 3 speed
1004: Resolver 4 speed
2001: 2048, 1 Vpp, A/B C/D R
2002: 2048, 1 Vpp, A/B R
2003: 256, 1 Vpp, A/B R
2004: 400, 1 Vpp, A/B R
2005: 512, 1 Vpp, A/B R
2006: 192, 1 Vpp, A/B R
2007: 480, 1 Vpp, A/B R
2008: 800, 1 Vpp, A/B R
2010: 18000, 1 Vpp, A/B R distance-coded
r0395[0...n] Actual stator resistance / R_stator act
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 6300, 6730,
6731, 6732
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0396[0...n] Actual rotor resistance / R_rotor act
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: MDS, p0130 Func. diagram: 6730
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
p0400[0...n] Encoder type selection / Enc_typ sel
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C2(1, 4) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: EDS, p0140 Func. diagram: 1580, 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 10100 0