List of parameters
Parameter
1-493
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by OA applications such as DCC (Drive Control Chart) or FBLOCKS (free
function blocks).
Note: OA: Open Architecture
Description: Sets the signal source for bitwise data transfer.
These signals are available in BO: r8510.0 ... 7 for further interconnection.
Index: [0] = Send signal to BO: r8510.0
[1] = Send signal to BO: r8510.1
[2] = Send signal to BO: r8510.2
[3] = Send signal to BO: r8510.3
[4] = Send signal to BO: r8510.4
[5] = Send signal to BO: r8510.5
[6] = Send signal to BO: r8510.6
[7] = Send signal to BO: r8510.7
Dependency: Refer to: r8510
Description: Sets the signal source for bitwise data transfer.
These signals are available in BO: r8511.0 ... 15 for further interconnection.
Index: [0] = Send signal to BO: r8511.0
[1] = Send signal to BO: r8511.1
[2] = Send signal to BO: r8511.2
[3] = Send signal to BO: r8511.3
[4] = Send signal to BO: r8511.4
[5] = Send signal to BO: r8511.5
[6] = Send signal to BO: r8511.6
[7] = Send signal to BO: r8511.7
[8] = Send signal to BO: r8511.8
[9] = Send signal to BO: r8511.9
[10] = Send signal to BO: r8511.10
[11] = Send signal to BO: r8511.11
[12] = Send signal to BO: r8511.12
[13] = Send signal to BO: r8511.13
[14] = Send signal to BO: r8511.14
r7903 Hardware sampling times still cannot be assigned / HW t_samp free
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p8500[0...7] BI: Data transfer 0 bitwise / Transfer 0 bit
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p8501[0...21] BI: Data transfer 1 bitwise / Transfer 1 bit
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0