List of parameters
Parameter
1-435
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note: The individual bits are only set if the appropriate action has been initiated and successfully completed.
When motor rating plate parameters are changed, the final display is reset.
When setting the individual bits, all of the most significant bits are reset.
Description: Displays the data of an induction motor determined and accepted from the stationary motor data identification or
rotating measurement.
Dependency: Refer to: r3925
Description: Successfully completed component of the last rotating measurement carried out.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Motor/control parameters calculated (p0340
= 1, p3900 > 0)
Yes No -
02 Motor data identification carried out at
standstill (p1910 = 1)
Yes No -
03 Rotating measurement carried out (p1960 =
1, 2)
Yes No -
04 Motor encoder adjustment carried out
(p1960 = 1, p1990 = 1)
Yes No -
05 Motor encoder manually adjusted Yes No -
15 Motor equivalent circuit diagram parameters
changed
Changed Not changed -
r3927[0...n] Motor data identification induction motor data determined / MotID ASM dat det
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 p0350 accepted Yes No -
01 p0354 accepted Yes No -
02 p0356 accepted Yes No -
03 p0358 accepted Yes No -
04 p0360 accepted Yes No -
05 p0320 accepted Yes No -
06 p0410 accepted Yes No -
12 p1715 accepted Yes No -
13 p1717 accepted Yes No -
14 p1590 accepted Yes No -
15 p1592 accepted Yes No -
22 p0341 accepted Yes No -
24 p0348 accepted Yes No -
25 p1752 accepted Yes No -
r3928[0...n] Motor data identification synchronous motor data determined / MotId PEM dat det
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 p0350 accepted Yes No -
02 p0356 accepted Yes No -
06 p0410 accepted Yes No -
07 p0431 accepted Yes No -
08 p1952 accepted Yes No -
09 p1953 accepted Yes No -
12 p1715 accepted Yes No -