List of parameters
Parameter
1-253
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p0500, p1520, p1522, p1523, p1532
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values when setting the lower torque limit (p1521 > 0) can result in the motor accelerating in an uncontrol-
lable fashion.
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description: Sets the signal source for the upper or torque/force limit when motoring.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1523, p1532
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Description: Sets the signal source for the lower or torque/force limit when regenerating.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1532
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Description: Sets the scaling for the upper torque limit or the torque limit when motoring.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1522[0...n] CI: Torque limit upper/motoring / M_max upper/mot
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 5620,
5630, 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- - 1520[0]
p1523[0...n] CI: Torque limit lower/regenerative / M_max lower/regen
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 1610, 5620,
5630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- - 1521[0]
p1524[0...n] CO: Torque limit upper/motoring scaling / M_max up/mot scal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 5620, 5630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]