List of parameters
Parameter
1-425
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: P gain of the flux controller for an induction motor determined by the motor data identification.
This P gain can be changed after the identification and accepted in p1590 with p1910/p1960 = -3.
Dependency: Refer to: p1590, p1910
Description: Integral time of the flux controller for an induction motor determined by the motor data identification.
This integral time can be changed after the identification and accepted in p1592 with p1910/p1960 = -3.
Dependency: Refer to: p1592, p1910
Description: P gain of the current controller determined by the motor data identification.
This P gain can be changed after the identification and accepted in p1715 with p1910/p1960 = -3.
Dependency: Refer to: p1715, p1910
Description: Integral time of the current controller determined by the motor data identification.
This integral time can be changed after the identification and accepted in p1717 with p1910/p1960 = -3.
Dependency: Refer to: p1717, p1910
p3080 MotId flux controller P gain identified / Flux ctrl Kp ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [A/Vs] 999999.0 [A/Vs] 0.0 [A/Vs]
p3081 MotId flux controller integral time identified / Flux ctrl Tn ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p3082 MotId current controller P gain identified / I_ctrl Kp ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 18_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 [V/A] 100000.000 [V/A] 0.000 [V/A]
p3083 MotId current controller integral time identified / I_ctrl Tn ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [ms] 1000.00 [ms] 0.00 [ms]