Function diagrams
Free function blocks (FBLOCKS)
2-916
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-147 7200 – General information
- 7200 -
Function diagram
87654321
fp_7200_98_eng.vsd
DO: All Objects
SINAMICS S110
20.04.09 V04.04.00
FBLOCKS - General
<1> The “free function blocks” function is activated in a drive object via p0108[DO_No].18 = 1 (bit 18 = 1, corresponds to 40000 hex).
<2> The run-time group that belongs to a function block is entered, for every function block, in the particular parameter for the run-time group (e.g. p20032 for AND 0 to [7210]).
Run-time
group
<1>
Run-time group property Run-time group sampling time
0
1
.
.
.
9
p20000[0]
p20000[1]
.
.
.
p20000[9]
r20001[0]
r20001[1]
.
.
.
r20001[9]
9999 Function block is not calculated
Activation
p0108[DO_No].18 (0)
<2>
General