List of parameters
Parameter
1-61
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the "active" or "inactive" state of an encoder interface (Sensor Module).
Value: 0: Component inactive
1: Component active
Dependency: Refer to: p0145, p0480, p0897
Description: Displays the version of the EEPROM data of the Sensor Module.
Dependency: Refer to: r0127
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the firmware version of the Sensor Module.
Dependency: Refer to: r0018, r0128, r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Sets the component number for the reactor module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a filter module.
r0146[0...n] Encoder interface active/inactive / Enc_intf act/inact
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 -
r0147[0...n] Sensor Module EEPROM data version / SM EEPROM version
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0148[0...n] Sensor Module firmware version / SM FW version
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0162 Reactor module component number / Reactor comp_no
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 199 0