Setpoint channel
Function diagrams
2-857
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-95 3040 – Direction limitation and direction reversal
- 3040 -
Function diagram
87654321
fp_3040_98_eng.vsd
DO: SERVO
SINAMICS S110
14.07.09 V04.04.00
Setpoint channel - Direction limitation and direction reversal
<100> Only if the function module “extended setpoint channel“ is activated (r0108.8 = 1).
<100>
4000.00 μs
Refer to [1020.7]
r1114
Setp after lim
[3050.1]
1 = Inhibit negative direction
r1198.5
1 = Inhibit positive direction
r1198.6
[2505.3]
p1110
[2505.3]
p1111
0
1
0
0
1
0
n_limit setp
p1063[D]
n_set_1
[3030.8]
1 = Setpoint inversion
r1198.11
-1
0
1
[2505.3]
p1113