Parameter
List of parameters
1-432
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the address of the signal source for the variable signaling function.
Dependency: Refer to: p3291
Caution: If an incorrect address and data type are set, then this can cause the software to crash.
Note: This parameter should only be set for p3291 = 1.
Description: Sets the data type of the signal source for the variable signaling function.
Value: 0: Unknown
1: U8, Unsigned8
2: I8, Signed8
3: U16, Unsigned16
4: I16, Signed16
5: U32, Unsigned32
6: I32, Signed32
7: Float, FloatingPoint32
Dependency: Refer to: p3291
Caution: If an incorrect address and data type are set, then this can cause the software to crash.
Note: This parameter should only be set for p3291 = 1.
Description: Displays the output signal for the variable signaling function.
Dependency: Refer to: p3290, p3291, p3295, p3296, p3297, p3298
p3292 Variable signaling function signal source address / Var sig S_src addr
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: 5301
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p3293 Variable signaling function signal source data type / Var sig S_src type
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: 5301
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 7 0
r3294 BO: Variable signaling function output signal / Var sig outp_sig
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: 5301
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -