Parameter
List of parameters
1-510
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the communication parameters for CANopen Receive Process Data Object 8 (RPDO 8).
Index: [0] = PDO COB-ID
[1] = PDO transmission type
Dependency: A valid COB-ID can only be set for the available (existing) channel.
Refer to: p8741
Note: Corresponds to the CANopen object 1407 hex + 40 hex * x (x: Drive number 0 ... 7).
Transmission types 0, 1, FE and FF can be set.
PDO: Process Data Object
Description: Sets the mapping parameters for CANopen Receive Process Data Object 1 (RPDO 1).
Index: [0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note: Corresponds to the CANopen object 1600 hex + 40 hex * x (x: Drive number 0 ... 7).
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
Description: Sets the mapping parameters for CANopen Receive Process Data Object 2 (RPDO 2).
Index: [0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note: Corresponds to the CANopen object 1601 hex + 40 hex * x (x: Drive number 0 ... 7).
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8707[0...1] CAN Receive PDO 8 / Receive PDO 8
SERVO_S110-CAN Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9204
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 8000 06DF hex [0] 8000 06DF hex
[1] 00FE hex
p8710[0...3] CAN Receive Mapping for RPDO 1 / Mapping RPDO 1
SERVO_S110-CAN Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9204, 9206
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p8711[0...3] CAN Receive Mapping for RPDO 2 / Mapping RPDO 2
SERVO_S110-CAN Can be changed: C1(3), T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9204, 9206
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex