Siemens SINAMICS S110 - r1732 CO: Direct-axis voltage setpoint; Direct U set; r1733 CO: Quadrature-axis voltage setpoint; Quad U set; p1752[0...n] Motor model changeover speed operation with encoder; MotMod n_chgov enc; p1755[0...n] Motor model changeover speed encoderless operation; MotMod n_chgSnsorl

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-266
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the direct-axis voltage setpoint Ud.
Description: Displays the quadrature-axis component of voltage setpoint Uq.
Description: Sets the speed to change over the motor model for operation with encoder.
Dependency: Refer to: p1756
Note: Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
Description: Sets the speed to change over the motor model to encoderless operation.
Dependency: Refer to: p1756
Note: The changeover speed applies for the changeover between open-loop and closed-loop control mode.
r1732 CO: Direct-axis voltage setpoint / Direct U set
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 1630, 5714,
6714, 5718
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Scaling: p2001 Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1733 CO: Quadrature-axis voltage setpoint / Quad U set
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 1630, 5714,
5718, 6714, 6719
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Scaling: p2001 Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
p1752[0...n] Motor model changeover speed operation with encoder / MotMod n_chgov enc
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 210000.00 [rpm]
p1755[0...n] Motor model changeover speed encoderless operation / MotMod n_chgSnsorl
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 210000.00 [rpm]