List of parameters
Parameter
1-45
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the effective Drive Data Set (DDS).
Dependency: Refer to: p0820, r0837
Note: The drive data set changeover is suppressed when selecting the motor identification, during the rotating measure-
ment, the encoder calibration and the friction characteristic record.
Description: Displays the status word of the closed-loop control.
Note: Re bit 04:
The bit is immediately set after power-on
Exception:
For an induction motor with brake (except for p1215 = 2), the bit is only set when 60% of the reference flux is
reached.
Description: Displays the actual speed setpoint at the input of the speed controller or U/f characteristic (after the interpolator).
Dependency: Refer to: r0020
Note: The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0051.0...1 CO/BO: Drive Data Set DDS effective / DDS effective
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DDS eff., bit 0 ON OFF -
01 DDS eff., bit 1 ON OFF -
r0056.1...15 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1530, 2526
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 De-magnetizing completed Yes No -
04 Magnetizing completed Yes No 2701
08 Field weakening active Yes No -
14 Vdc_max controller active Yes No -
15 Vdc_min controller active Yes No -
r0060 CO: Speed setpoint before the setpoint filter / n_set before filt.
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2701, 2704,
5020, 6030, 6799
P-Group: Displays, signals Units group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]