Parameter
List of parameters
1-274
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the identified reluctance torque constant.
Dependency: Refer to: r1937, r1938, p1959, p1960, r1969
Note: This value corresponds to the reluctance torque constant (p0328).
Description: Displays the identified, optimum load angle.
Note: This value corresponds to the optimum load angle (p0327).
Description: Displays the identified magnetizing current.
Dependency: Refer to: r1936, p1959, p1960
Note: This value corresponds to the magnetizing current (p0320 / r0331).
Description: The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency: Refer to: r1951
Description: The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency: Refer to: r1950
r1939 Reluctance torque constant identified / kT_reluct ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1947 Optimum load angle identified / phi_load ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [°] - [°] - [°]
r1948 Magnetizing current identified / I_mag ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1950[0...19] Voltage emulation error voltage values / U_error U_values
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r1951[0...19] Voltage emulation error current values / U_error I_error
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]