EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-188 9912 - Control word interconnection

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic Operator Panel 20 (BOP20)
Function diagrams
2-963
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-188 9912 – Control word interconnection
- 9912 -
Function diagram
87654321
fp_9912_98_eng.vsd
DO: CU_S110
SINAMICS S110
27.10.08 V04.04.00
Basic Operator Panel 20 (BOP20) - Control word interconnection
STW BOP.0
STW BOP.1
STW BOP.2
STW BOP.3
STW BOP.4
STW BOP.5
STW BOP.6
STW BOP.8
STW BOP.9
STW BOP.11
STW BOP.12
STW BOP.13
STW BOP.14
STW BOP.15
STW BOP.7
STW BOP.10
p0848[0] = r0019.2
-
-
-
-
p2102[0] = r0019.7
-
-
-
-
-
-
p0840[0] = r0019.0
p0844[0] = r0019.1
1 = On
0 = OFF (OFF1)
1 = No coast down
0 = Coast down (OFF2)
1 = No fast stop
0 = Fast stop (OFF3)
= Acknowledge fault
Reserved
Reserved
Reserved
Reserved
Interconnection STW BOP (r0019)
Signal
Interconnection
parameters
Meaning
Refer to [1020.7]
PROFIdrive sampling time
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
<1>
<1> The BICO interconnection represents an example that can be be changed by the user.
p1035[0] = r0019.13
p1036[0] = r0019.14
1 = Motorized potentiometer, raise
1 = Motorized potentiometer, lower

Table of Contents