EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-123 4730 - Encoder interface, send signals, encoders 1... 2

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Encoder evaluation
Function diagrams
2-889
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-123 4730 – Encoder interface, send signals, encoders 1 ... 2
- 4730 -
Function diagram
87654321
fp_4730_98_eng.vsd
DO: SERVO
SINAMICS S110
03.03.08 V04.04.00
Encoder evaluation - Encoder interface, send signals, encoders 1 ... 2
From the measuring probe
evaluation
[4740.4]
Feedback signal of the active function (1 = function active)
r0481[n-1]
Enc Gn_ZSW
<1>
<1> Index [n-1] --> encoder n
Index [0] --> encoder 1
Index [1] --> encoder 2
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Status word from encoder n (n = 1, 2 or 3)
1 = Position actual value from function 1
1 = Position actual value from function 2
1 = Position actual value from function 3
1 = Position actual value from function 4
1 = Measuring probe 1 deflected (high signal)
1 = Measuring probe 2 deflected (high signal)
Reserved
1 = Acknowledge encoder fault active
Reserved (for reference point offset)
Absolute value is cyclically transferred
Encoder fault, the fault is in Gn_XIST2 (r0483)
Parking encoder active (i.e. the encoder is not operational)
Bit 0
Bit No.
Bit 12
Bit 13
Bit 14
Bit 15
Generated value
in Gn_XIST2
(and can be
read)
Encoder status bits
from the position sensing, encoder n
[4704.8]
to the sequence control for Gn_XIST2
[4704.5]
Position value 2 from encoder n
The contents of position actual value 2 (Gn_XIST2) at [4704] depends on Gn_STW and Gn_ZSW.
This can be done as follows:
- Undefined for a parking encoder (Gn_ZSW.14 = 1).
- For Gn_ZSW.15 = 1 the fault code for encoder faults is located here.
- Position actual value at the reference mark (for Gn_STW.7 = 0 and Gn_ZSW.4-7 > 0; with handshake).
- Position actual value due to flying measurement (for Gn_STW.7 = 1 and Gn_ZSW.4.7 > 0; with handshake).
- Cyclic absolute position value (free-running value, e.g. from the EQN absolute track (for Gn_ZSW.13 = 1).
4
3
2
1
Function
No.
For reference number and flying
measurement
reference mark 1 or measuring probe 1
reference mark 2 or measuring probe 1
reference mark 3 or measuring probe 2
reference mark 4 or measuring probe 2
PROFIdrive bit
Refer to [1020.7]
PROFIdrive sampling time
NOTE:
SINAMICS S110 supports only one encoder. This encoder may be parameterized as encoder 1 or encoder 2.

Table of Contents