Servo control
Function diagrams
2-905
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-138 5630 – Upper/lower torque limit
<3>
- 5630 -
Function diagram
87654321
fp_5630_98_eng.vsd
DO: SERVO
SINAMICS S110
30.10.08 V04.04.00
Servo control - Upper/lower torque limit
p1520[D]
M_max upper/mot
-1 000 000.00...20 000 000.00 [Nm]
p1520[D] (100.00)
M_max upper/mot
(1520)
p1522[C]
<1>
<1> For p1400.4 = 0 the torque limits for the positive and negative torque direction (upwards and downwards) are compatible with MASTERDRIVES and MICROMASTER 4.
"Normal case":
If neither dynamic limits nor offsets are required, the upper torque limit is entered via p1520 and the lower via p1521 (as a negative value).
Upper torque limit
M_max up/mot scal
(1524)
p1528[C]
p1521[D]
M_max lower/regen
-20 000 000.00...1 000 000.00 [Nm]
p1521[D] (-100.00)
M_max lower/regen
(1521)
p1523[C]
<1>
Lower torque limit
M_max low/gen scal
(1525)
p1529[C]
p1520
{p1522}
p1532
p1521
M
{p1523}
B
<2>
<2>
<3> The limiter ensures that the limits do not mutually "overtake" one another.
M
n
43
M
n
21
A
F07090
A B
, Fault F07090 is initiated, which can also be disabled.
With <
1000.00 μs
<4> For the manufacturer-specific PROFIdrive telegrams 102 und 103, r1543 is switched in here [5610.4].
<4>
e.g. from MOMRED
<2>
<2>
<4>
e.g. from MOMRED
[5640.1]
[5640.1]
M_max offset
M_max offset
+
+
+
+
M_max offset
-100 000.00...100 000.00 [Nm]
p1532[D] (0.00)
0
1
0
1
(1)
M_lim var/fixS_src
p1551[C]
Example:
0 = Quick stop activated
(OFF3)
r0899.5
p1524[D]
M_max upper/mot scal
-2000.0...2000.0 [%]
p1524 (100.0)
p1525[D]
M_max low/gen scal
-2000.0...2000.0 [%]
p1525 (100.0)
A
<2> Danger: or positive values at represent a minimum torque for the other torque direction and can cause the motor to accelerate uncontrollably.
B
Negative values at
!
M_max 1
M_min 1
r1527
M_max low w/o offs
r1526
M_max up w/o offs