List of parameters
Parameter
1-477
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the files to adapt the file system.
Description: Setting to adapt the file system on the non-volatile memory.
Example:
The result data "clamping cycle thresholds" are available (r5005.1 = 1) and should be reset.
--> set p5007.1 = 1: select result data "clamping cycle thresholds".
--> set p5009 = 1: initiate "reset" function for the file selected in p5007.
--> p5009 = 40: feedback signal during "operation running".
--> p5009 = 20: feedback signal for a successfully completed operation.
16 Characteristic data spindle available Yes No -
17 Characteristic data clamping cycle counter
available
Yes No -
19 Characteristic data operating hours counter
available
Yes No -
20 Characteristic data temperature diagnostics
available
Yes No -
22 Characteristic data speed/torque matrix
available
Yes No -
30 Characteristic data sensor description avail-
able
Yes No -
31 Characteristic data sensor calibration data
available
Yes No -
p5007 Spindle file system selection / File sys select
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
01 Result data clamping cycle thresholds
selected
Yes No -
02 Result data clamping cycle counter selected Yes No -
03 Result data operating hours counter
selected
Yes No -
04 Result data temperature diagnostics
selected
Yes No -
05 Result data real time clock synchronization
selected
Yes No -
06 Result data speed/torque matrix selected Yes No -
17 Characteristic data clamping cycle counter
selected
Yes No -
19 Characteristic data operating hours counter
selected
Yes No -
20 Characteristic data temperature diagnostics
selected
Yes No -
22 Characteristic data speed/torque matrix
selected
Yes No -
p5009 Adapt spindle file system / Adapt file sys
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting