Basic positioner (EPOS)
Function diagrams
2-871
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-107 3618 – Direct setpoint input/MDI mode, dynamic values (r0108.4 = 1)
- 3618 -
Function diagram
87654321
fp_3618_98_eng.vsd
DO: SERVO
SINAMICS S110
04.04.08 V04.04.00
EPOS - Direct setpoint input/MDI mode, dynamic values (r0108.4 = 1)
[3620.1]
4000.00 μs
Pos fixed value
-2147483648...2147483647 [LU]
p2690 (0)
p2690
v fixed value
1...2147483647 [1000 LU/min]
p2691 (600)
p2691
a_over fixed value
0.100...100.000 [%]
p2692 (100.000)
p2692
-a_over fixed value
0.100...100.000 [%]
p2693 (100.000)
p2693
[3620.1]
[3620.1]
[3620.1]
MDI s_set
(p2690)
p2642
MDI -a_over
(p2693)
p2645
MDI a_over
(p2692)
p2644
MDI v_set
(p2691)
p2643
100 %