Data sets
Function diagrams
2-951
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-178 8560 – Command Data Sets (CDS)
- 8560 -
Function diagram
87654321
fp_8560_98_eng.vsd
DO: SERVO
SINAMICS S110
16.06.08 V04.04.00
Data sets - Command Data Sets (CDS)
Not relevant
Refer to [1020.7]
CDS selected
r0836.0
r0836
CDS effective
r0050.0
r0050
r0836.1
r0050.1
BI: p0810 = "0"
CDS0 selected
r0836.0 = 0
BI: p0810 = "1"
CDS1 selected
r0836.0 = 1
CDS0 effective
r0050.0 = 0
CDS1 effective
r0050.0 = 1
t
Example:
Change over Command Data Set
CDS0 --> CDS1
t
t
<1> Min / Max / Factory setting: 1 / 2 / 2.
(0)
CDS select., bit 0
p0810
Copy CDS, source
p0809[0] (0)
Copy CDS, target
p0809[1] (1)
Copy CDS, start
p0809[2] (0)
Drive 1
CDS1
CDS0

Table of Contents