EasyManua.ls Logo

Siemens SINAMICS S110 - r0472[0...2] Redundant coarse position value relevant bits; Relevant bits; r0474[0...2] Redundant coarse position value configuration; Red pos config; r0475[0...2] Gx_XIST1 coarse position safe most significant bit; Gx_XIST1 safe MSB; r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1; Diag Gn_XIST1

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-117
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the number of relevant bits for the redundant coarse position value.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Description: Displays the encoder configuration for the redundant coarse position value.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: Refer to: p9315, p9515
Description: Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Note: MSB: Most Significant Bit
Description: Displays the encoder actual position value Gn_XIST1 according to PROFIdrive for diagnostics.
In contrast to r0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
r0472[0...2] Redundant coarse position value relevant bits / Relevant bits
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0474[0...2] Redundant coarse position value configuration / Red pos config
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Incrementer Yes No -
01 Encoder CRC least significant byte first Yes No -
02 Redundant coarse position val. most signifi-
cant bit left-aligned
Yes No -
r0475[0...2] Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dynamic index: - Func. diagram: 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -