Fig. 2-58 2505 – Control word, setpoint channel
- 2505 -
Function diagram
87654321
fp_2505_98_eng.vsd
DO: SERVO
SINAMICS S110
28.10.08 V04.04.00
Internal control/status words - Control word, setpoint channel
11
12
13
14
15
1 = Fixed setpoint, bit 0
Control word, setpoint channel
1 = Fixed setpoint, bit 1
Reserved
Reserved
Reserved
1 = Inhibit negative direction of rotation
1 = Inhibit positive direction of rotation
Reserved
Reserved
Reserved
Reserved
1 = Direction reversal
Reserved
Reserved
1 = Bypass ramp-function generator
Reserved
p1020[C]
(0)
Fixed setpoint selection, bit 0
p1111[C]
(0)
Inhibit positive direction
PROFIdrive bit
9
10
8
7
6
5
4
3
2
1
0
Bit No.
4000.00 μs
r1198.5
r1198.6
r1198.11
p1021[C]
(0)
Fixed setpoint selection, bit 1
r1198.1
r1198.0
p1113[C]
(0)
Setpoint inversion
To the setpoint channel [3060.1] [3070.3]r1198.15
p1122[C]
(0)
Bypass RFG
To fixed speed setpoints [3010.2]
To fixed speed setpoints [3010.2]
To direction of rotation limiting and
direction of rotation reversal [3040.3]
To direction of rotation limiting and
direction of rotation reversal [3040.5]
To direction limiting and direction reversal
[3040.2]
p1110[C]
(0)
Inhibit negative direction
r1198
STW setpoint channel