Parameter
List of parameters
1-414
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets a fixed setpoint for the acceleration override.
Dependency: Refer to: p2572, p2644
Note: As standard, the following BICO interconnection is established: CI: p2644 = r2692
The percentage value refers to the maximum acceleration (p2572).
Description: Sets a fixed setpoint for the deceleration override.
Dependency: Refer to: p2573, p2645
Note: As standard, the following BICO interconnection is established: CI: p2645 = r2693
The percentage value refers to the maximum deceleration (p2573).
Description: Display and connector output for the reference quantity for speed and frequency (p2000).
All speeds or frequencies specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
The following applies: Reference frequency (in Hz) = reference speed (in rpm) / 60
This parameter has the unit rpm.
Dependency: Refer to: p2000
Note: This parameter provides the numerical value of the reference quantity p2000 as a connector output for interconnec-
tion with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector output in
DCC.
Description: Connector output of the reference quantity for voltages p2001.
p2692 CO: EPOS acceleration override, fixed setpoint / a_over fixed val
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 3618
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.100 [%] 100.000 [%] 100.000 [%]
p2693 CO: EPOS deceleration override, fixed setpoint / -a_over fixed val
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 3618
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.100 [%] 100.000 [%] 100.000 [%]
r2700 CO: Reference speed/reference frequency / n_ref/f_ref
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r2701 CO: Reference voltage / Reference voltage
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -