SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
63: MotID: Reluctance constant measurement end
70: MotID: Moment of inertia measurement, step 1
71: MotID: Moment of inertia measurement, step 2
72: MotID: Moment of inertia measurement, step 3
73: MotID: Moment of inertia measurement end
80: MotID: Magnetizing inductance measurement, step 1
81: MotID: Magnetizing inductance measurement, step 2
82: MotID: Magnetizing inductance measurement, step 3
83: MotID: Magnetizing inductance measurement evaluation
84: MotID: Magnetizing inductance measurement end
90: MotID: Saturation characteristic. step 1
91: MotID: Saturation characteristic. step 2
92: MotID: Saturation characteristic. step 3
93: MotID: Saturation characteristic evaluation 1
94: MotID: Saturation characteristic evaluation 2
95: MotID: Saturation characteristic end
96: MotID: Converter model, step 1
97: MotID: Converter model, step 2
98: MotID: Converter model, step 3
99: MotID: Converter model, step 4
100: PolID: Motion-based, step 1
101: PolID: Motion-based, step 2
102: PolID: Motion-based, step 3
103: PolID: Motion-based, step 4
104: PolID: Motion-based, step 5
Description: Displays the effective Motor Data Set (MDS) and the effective Encoder Data Sets (EDS).
Index: [0] = Motor Data Set MDS effective
[1] = Encoder 1 Encoder Data Set EDS effective
[2] = Encoder 2 Encoder Data Set EDS effective
[3] = Reserved
Dependency: Refer to: p0186, p0187, p0188, r0838
Note: Value 99 means the following: No encoder assigned (not configured).
Description: Displays the effective Command Data Set (CDS).
Dependency: Refer to: p0810, r0836
Note: The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0049[0...3] Motor data set/encoder data set effective / MDS/EDS effective
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8565
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0050.0...1 CO/BO: Command Data Set CDS effective / CDS effective
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8560
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 CDS eff., bit 0 ON OFF -
01 CDS eff., bit 1 ON OFF -