PROFIdrive
Function diagrams
2-807
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-50 2481 – IF1 receive telegram, free interconnection via BICO (p0922 = 999)
- 2481 -
Function diagram
87654321
fp_2481_98_eng.vsd
DO: CU_S110
SINAMICS S110
16.11.08 V04.04.00
PROFIdrive - IF1 receive telegram, free interconnection via BICO (p0922 = 999)
PROFIBUS
PROFINET
PZD receive word 1
PZD receive word 2
PZD receive word 5
r2050[1]
r2091.15
PZD receive word 3
PZD receive word 4 r2050[3]
r2050[2]
r2050[4]
Reference quantities for further interconnection
p200x
<1>
<1> The following representation applies for words: 4000 hex = 100 %.
The reference variables p200x apply for the ongoing interconnection (100 % -> p200x).
The following applies for temperature values: 100 °C -> 100 % = 4000 hex; 0 °C -> 0 %.
PROFIdrive
receive telegram
Drive object n
Header
Drive object 1
Drive object 2
.
.
.
.
.
.
Drive object m
Trailer
Refer to [1020.7]
PROFIdrive sampling time
r2091.0
r2090.0
r2050[0]
r2090.15