Parameter
List of parameters
1-118
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Caution: Following ramping-up or after a data set changeover, the new value is present at connector inputs which are inter-
connected to connector output r0479 and under certain circumstances take 100 ms to become available.
Reason:
These interconnections are updated in the background, unlike interconnections involving other connector outputs
(e.g. CO: r0482).
The value is immediately available when non-cyclically reading r0479 (e.g. via the expert list).
Description: Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished:
CI: p0480[0] = r2520[0], CI: p0480[1] = r2520[1] and CI: p0480[2] = r2520[2]
Description: Displays the encoder status word Gn_ZSW according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Notice: Information on Gn_STW/Gn_ZSW can, e.g. be found in the following literature:
SINAMICS S120 Function Manual Drive Functions
Note: Re bit 14:
Displays the acknowledgement for "activate parking encoder" (Gn_STW.14 = 1) or encoder position actual value
(Gn_XIST1) invalid.
p0480[0...2] CI: Signal source for encoder control word Gn_STW / Enc S_src Gn_STW
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Integer16 Dynamic index: - Func. diagram: 1580, 4720
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r0481[0...2] CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 4010, 4704,
4730
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Function 1 active Yes No -
01 Function 2 active Yes No -
02 Function 3 active Yes No -
03 Function 4 active Yes No -
04 Value 1 Displayed in r0483 Not present -
05 Value 2 Displayed in r0483 Not present -
06 Value 3 Displayed in r0483 Not present -
07 Value 4 Displayed in r0483 Not present -
08 Measuring probe 1 deflected Yes No -
09 Measuring probe 2 deflected Yes No -
11 Encoder fault acknowledge active Yes No 9676
13 Absolute value cyclically Displayed in r0483 No -
14 Parking encoder active Yes No -
15 Encoder fault Displayed in r0483 None -