List of parameters
Parameter
1-601
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: p9762
Note: The new password entered into p9762 must be re-entered in order to acknowledge.
p9762 = p9763 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
Description: Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions inte-
grated in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency: Refer to: p9705
Refer to: C01798
Description: Displays the Safety Integrated version for the drive-integrated safety functions on processor 1.
Index: [0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Dependency: Refer to: r9890
Note: Example:
r9770[0] = 2, r9770[1] = 60, r9770[2] = 1, r9770[3] = 0 --> Safety version V02.60.01.00
Description: Displays the Safety Integrated monitoring functions supported on processor 1 and processor 2.
Processor 1 determines this display.
r9765 SI Motion forced check procedure remaining time (Control Unit) / SI Mtn dyn remain
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [h] - [h] - [h]
r9770[0...3] SI vers. safety fcts that run indep. in the drive (processor 1) / SI version Drv P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2802
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9771 SI common functions (processor 1) / SI general fct P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 2804
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 STO supported via terminals Yes No 2804
01 SBC supported Yes No 2804
02 Extended Functions supported (p9501 > 0) Yes No 2804
03 SS1 supported Yes No 2804
04 Extended Functions PROFIsafe supported Yes No -
05 Extended Functions integrated in drive sup-
ported (p9601.2 = 1)
Yes No -
06 Basic Functions PROFIsafe supported Yes No -
07 Extended Functions encoderless supported Yes No -
08 Safe Brake Adapter supported Yes No -